disconnecting uefi drivers hangs in R620 server
Hello,sometimes when i reset a R620 dell server in the booting process it hangs in Disconnecting uefi drivers screen.Could you help me in what could be the reason? Thanks,Cristina.
View ArticleMemory on SC1435
I have added 16 GB of ram. Server is not giving me error on booting about not being an optimal configuration, but it can only see 8. If I put the old chips of 512 and 512 and then one 4 GB. The server...
View ArticlePowerEdge T300 CPU Upgrade
I was wanting to upgrade my E5345 to a E5472. TDP was roughly the same as well as they should both be LGA 771 socket chips. Has anyone done this if so was there something you had to do to get the E5472...
View ArticleR730 VMware 5.5 U2 PSoD using passthrough GPU's
I have two R730's one running VMware 5.5 U1 and one running VMware U2 they are both getting random PSoD with uncorrectable bus errors I was wondering what would be the best method of troubleshooting...
View ArticleDell poweredge 1951 backlane SCSI card
Hi everyoneI have installed and running a Dell poweredge 1950 which i use it for backup(on tape) using Backup EXEC 2014. In the back lane there is an empty slot for a expansion SCSI card to where a...
View ArticleiDRAC 6 Enterprise not showing storage
Hi,we have a Dell PowerEdge R710 with iDRAC 6 Enterprise.When I open the iDRAC web interface, there is no information or status of the Perc H310 RAID controller.I can't see physical disks, no virtual...
View ArticleAdding additional drive space to Perc 6/i R710 Server
I currently have 3 250gb drives setup as a raid 5 (original configuration) on a R710 server with a Perc 6/i controller. I have ordered 3 more drives (same drives) as we are running out of disk space....
View ArticleAutoCAD DXF Files for VTRX?
Does anybody know where I can get AutoCAD files for Dell hardware. In particular I'm looking for a .DXF or .DWG for the PowerEdge VRTX Enclosure with 12 3.5" HD arrangement and half-height server...
View ArticlePowerEdge R815 Optimal Memory Configuration
Hi everyone,I am running PowerEdge R815 with 128GB of memory (8Sticks of 16GB) I have tried every memory configuration i knew of and it still gives me 'memory configuration is not optimal, Press F1 to...
View ArticleM1000e CMC Redundancy issues since Firmware 5.00 upgrade
Hi,We are seeing a lot of the following alerts"Chassis management controller (CMC) redundancy is lost".and 30 seconds later"The chassis management controller (CMC) is redundant"on our fleet (47) of...
View ArticlePicking the right SSD's for Power Edge R710
Hello,We have a PE R710 as a Virtual Host. One of our VM's demands high Read/Write. Our R710 has 6 drive bays which 2 are used for the OS. The R710 has a Perc 6/i.I would like to use the other 4 bays...
View ArticlePE R410 in LCD display
Nothing comes back from Google or forum search - system boots fine but this appears constant in the LCD display ? Worry, forget or ignore ?-- Stuart
View ArticleDell System Hardware & Software Updates for January 26th – 30th 2015
Popular DownloadsDell Server E-Support Tool for Dell ServersDell Server Update Utility, v.14.10.200.117 (Optional) 10/15/2014 Dell Support Live Image Version 2.1 (Recommended) 7/23/2014 Server...
View ArticleDell T420 - configuring memory
Hello!We have just bought Dell T420 with H710 controller inside. It has DELL 370-21961 (samsung 16gb) memory installed. But after first start it is only writing on the screen: "Configuring memory..."...
View ArticleFiber card not showing in firmware Inventory
I have two M620 blades in a 1000e chassis that has QLogic fiber cards that show up in the hardware inventory, but not the firmware inventory. I have eight other blades in that chassis that they show...
View ArticleDell Vrtx w/PowerEdge M520 blade servers
My company just recently purchased this set up in order to virtualize our servers with VMware esxi.I have set up the environment with shared storage from the vrtx etc. and the VMware environment is up...
View ArticleMemory and Processor Error After memory upgrade
HII have one R710 with 2 x4 GB memory . I upgraded that to 6 X4GB .Now total memory is 24GB with two CPU. After that server gives memory and processor errors randomly DIMM_A1 DDR3 - Synchronous...
View ArticleDell Poweredge R510 II - OEM or One Off?
This here is a bit odd, but has anyone ever seen a system like this? I picked up a Poweredge today, no model markings on the chassis for $10, quite nice specs too.The odd part is there's absolutely no...
View ArticleT620 Part List
Does dell have any document or download similar to the hp quick specs which shows the list of part number for the serverBasically a data sheet of all the partsThe reason why I am asking is I am looking...
View ArticlePower on
We have a Dell PowerEdge 2900 III that had some issues with the power on button. We resolved them we thought. Now we've moved the server very gently and now it won't power up at all. We removed the...
View Article