Quantcast
Channel: PowerEdge General HW Forum - Recent Threads
Viewing all 5887 articles
Browse latest View live

PowerEdge VRTX with R1-2401 VRTX 1Gb Switch Module - cannot connect port gi1/1

$
0
0

I don't know if this is a server or network issue, but I post here anyway..

Trying to set up a Dell PowerEdge VRTX with a R1-2401 VRTX 1Gb Switch Module. But port gi1/1 insists that is in a down/down state. The OS also says not connected. What I am doing wrong? All other ports are connected fine.

This is a M620 server, if that helps at all.

 


How to upgrade Lifecycle Controller with no OS

$
0
0

Trying to upgrade the Lifecycle Controller software on an R320 with no OS installed.  Only options I can find for download are DUPs for Win and Linux.  How would I go about updating the LCC with no OS installed?  Have LCC version 1.4.0.128 and trying to go to 1.4.2.12.

Disabling management shared NIC (BMC) on PowerEdge T410

$
0
0

Hi, first I would like to thank everyone in advance.

I have PowerEdge T410 (11G, BMC only - no IDRAC card), and this server will be moved to some "unfriendly" network, with big risk of some remote access exploitation, but with absolutely no need for remote administration. Therefore I'd like to completely disable BMC management NIC functionality. So far i managed to disable IPMI in BMC setup utility (CTRL+E) and SOL (Serial-Over-Lan) with OMSA. And I'd like to know some best practises for this situation.

In the T410 HW Owner's Manual there is some mention on page 47, where system message "MANAGEMENT SHARED NIC=<DISABLED | ENABLED>" is mentioned. It says management shared NIC can be enabled/disabled by some "System Management software", so this might be some way to go, but i don't know which exactly utility to use.

So finally the question is: What utility to use for disabling management shared NIC for integrated NICs, while keeping its normal usability by OS?

Sorry for long introduction, thank you very much, Jakkie.

PowerEdge T20 support dual rank 4 GB (1 module(s) 4 GB) DDR3, unbuffered, ECC, 1,600 MHz, DIMM, dual rank?

$
0
0

Hello!

I have 4GB module (dual rank) = 16G:

2 module Dual Rank SAMSUNG Memory, 2 module Dual Rank HYNIX Memory.

Can I install this memory to socket PowerEdge T20?

PowerEdge T20 support dual rank 4 GB (1 module(s) 4 GB) DDR3, unbuffered, ECC, 1,600 MHz, DIMM, dual rank?

If support, how install 4 module on socket schema?

Thank you.

p.s. sorry for my bad english.

Dell power edge t20 ram

$
0
0
I am going to be buying a dell power edge t20 so I want to replace some of the stock ram for larger ram this was my thinking on to do is use 2 out of the udimms that it ships with then put into the other 2 slots with this ram (8GBx2) DDR3 1600 MT/s (PC3-12800) CL9 @1.5V UDIMM 240-Pin Memory would the server operate just fine with the 18gb of ram? P.S. I relocated this question from a answered question to make eased to work with.

possible can restore the DATA from Lost partition Raid 5?

$
0
0

we have 2 drives in our partition using  raid 5 poweredge r420 , then the target was to format drive c : they used Manage CD/DVD SMTD,  so its end bad situation .  partition D was lost.

any solution to restore back the data?

thanks.

Dell PowerEdge 2900 III - CPU Upgrade Xeon x5492 3.4 Ghz

$
0
0

Hoping someone can confirm if a Dell PowerEdge 2900 III supports an Intel Xeon x5492 3.4Ghz.  Latest Bios 2.7 shows support for 5400 series.  Any information is appreciated.

DSM Storage Service Stopped

$
0
0

We have a server that is repeatedly throwing out errors to SCOM that "DSM Storage Service Stopped"

"DSM Storage Service is in a Critical State as the Service has stopped. Try Restarting the Service."
It occurs exactly every 10 minutes.
I do not see anything posted to any event log
The system is a PowerEdge R620 running Windows Server 2012 Core as a Hyper-V host
SA version is 7.3
 
Thanks

VMware AutoDeploy with the Integrated Dell SD Card

$
0
0

Hi Chris

is there a way to use VMware AutoDeploy with the Integrated Dell SD Cards. We moved from full Installs on the integrated SD Cards to AutoDeploy but I am unable to Use them for Stateless Cashing.

Ruan

dell R720 issue

$
0
0
Hi can you help please to my customer with this issue? The servers we use have 4 NIC's 2 X 1Gig 2 X 10Gig Unlike any other hw we had in the past, the Linux detects the ports as follow - eth0 = 10G #1 eth1 = 10G #2 eth2 = 1G #3 eth3 = 1G #4 On another HW it is detected as follow - eth0 = 1G #3 eth1 = 1G #4 eth2= 10G #1 eth3 = 10G #2 This fact ( 10 G before 1G ) complicates the installation, please check with dell if it’s possible to change the order of the Nics. Anther example - In the Idrac we see - NIC.Integrated.1-1-1 Ethernet = C8:1F:66:ED:02:35

RAM upgrade for PowerEdge T410 - What works?

$
0
0

We have a from-the-factory configured Dell PowerEdge t410 server purchased in 07/2011 which we would like to now upgrade to 48GB RAM at the least cost possible as we are a non-profit trying to stretch our dollars.  It currently has 24GB installed (six DDR3 1333MHz registered dual rank 4GB RDIMMs installed in slots A1-A3 and B1-B3 (optimizer mode).  The machine has two Intel Xeon E5630 processors.  According to OMSA the BIOS is version 1.6.3 released 02/01/2011.  The server runs Windows Server 2008 R2 Enterprise and is the host system to 3 Hyper-V machines also running Server 2008.  All has gone well, but we are seeing the need to allocate more memory to the VMs and it isn't there, thus the need to upgrade.

I'm no hardware/server guru, but have done a little research and was hoping that we could purchase and install either 2 8GB sticks (add to empty slots) to take the system to 40GB; or buy 4 8GB sticks (& remove 2 4GB sticks) to take the system to 48GB.  If we could afford it, the latter would be preferred.  Here's the RAM I was looking to purchase:  http://accessories.us.dell.com/sna/productdetail.aspx?c=us&l=en&s=bsd&cs=04&sku=A6996808&baynote_bnrank=0&baynote_irrank=0&~ck=baynoteSearch

My problem is that I am very confused by the diagrams, and the 'rules' I've read in the manual as to what will work.  I've also read some forums indicating that I may need to upgrade BIOS.

So, do I need to upgrade BIOS?

Can I purchase the memory above (hopefully 4 modules) and install them for a 48GB working system?  If so, how do I configure module placement?  I was thinking 4GB sticks in slots 4 & 1 (both A & B making 8GB channels); and 8GB sticks in slots 2 & 3 (both A & B - single channel slots so each their own channel with 8GB each) or is this wrong?

Your help would be appreciated.  Thank you.

re: PowerEdge 2900 I, II, and III

$
0
0

Hi:

Can anyone explain the difference between the various PowerEdge 2900 versions.  There were three total: I, II, and III.

Thanks,

David

Optimal memory config

$
0
0

I added some more memory  to a couple R710s and both are displaying at boot that they have a non-optimal configuration, although they still run.  Below is my current config, is there a way to use these chips so both boxes get 128GB?  If I need to buy more/different chips let me know.  I thought I was following the R710 memory configuration guides properly, but apparently not.


Server 1 Xeon X5647:

A1: 16GB (1333 mhz)

A2: 16GB (1333 mhz)

A3: 16GB (1333 mhz)

A4: 4GB (1333 mhz)

A5: 4GB (1333 mhz)

A6: 4GB (1333 mhz)

A7: 4GB (1333 mhz)

A8: EMPTY

A9: EMPTY

B1: 16GB (1333 mhz)

B2: 16GB (1333 mhz)

B3: 16GB (1333 mhz)

B4: 4GB (1333 mhz)

B5: 4GB (1333 mhz)

B6: 4GB (1333 mhz)

B7: 4GB (1333 mhz)

B8: EMPTY

B9: EMPTY

Server 2 Xeon X5647:

A1:8GB (1333 mhz)

A2:8GB (1333 mhz)

A3:8GB (1333 mhz)

A4:8GB (1333 mhz)

A5:8GB (1333 mhz)

A6:8GB (1333 mhz)

A7:16GB (1333 mhz)

A8:EMPTY

A9:EMPTY

B1:8GB (1333 mhz)

B2:8GB (1333 mhz)

B3:8GB (1333 mhz)

B4:8GB (1333 mhz)

B5:8GB (1333 mhz)

B6:8GB (1333 mhz)

B7:16GB (1333 mhz)

B8:EMPTY

B9:EMPTY

Perc H200e latest drivers and Firmware

$
0
0

Hi,

I'm trying to find the latest for the above.

When running OMSA 7.3 it says that the latest available Firmware version is 07.03.06.00

But I can't find that anywhere on dell.com.

Can someone pls help?

ta,

John Bradshaw

PowerEdge R910 4x16GB issue

$
0
0

I have PowerEdge R910 with two memory riser cards and 4x4GB mem modules.

I tried to replace 4x4GB with 4x16GB memory modules (16GB 1333MHz Reg ECC Low Voltage Module ) and during POST system halt with message

NON CONFIGURABLE MEMORY DETECTED

SYSTEM HALTED

BIOS is updated on the last revision.

Is there any explanation?

Is 4x16GB supported on the R910 server?

 

Dragan


Dell System Hardware & Software Updates for Week of August 11th ~ 15th 2014

$
0
0

Dell System Hardware & Software Updates for

August 11th ~ 15th 2014

 

Popular Hardware Updates:

Dell DSET: http://dell.to/1pb7oH9 

Dell Server Update Utility, v.14.07.00 (Optional) 7/23/2014 http://dell.to/1zSrR6e

Dell Support Live Image Version 2.1 (Recommended) 7/23/2014 http://dell.to/1oAh3Wm

 

Hardware Updates:

Dell Chassis Management Controller (CMC) for Dell PowerEdge VRTX, Version 1.35 (Recommended) 7/30/2014 http://dell.to/1sG4qMD

OpenManage Integration for VMware vCenter 2.1 (Recommended) 7/30/2014 http://dell.to/1palmrL

Dell PowerEdge T20 System BIOS A04 (Recommended) 7/31/2014 http://dell.to/1BgyZuX

Dell Repository Manager, v1.9.1 PATCH (Optional) 7/30/2014 http://dell.to/1oQUIo0

PowerVault 124T Firmware Update Release A23 (Recommended) 7/30/2014 http://dell.to/1qa332F

Dell PowerVault MD32/MD34/MD36/MD38 Series Resource DVD 5.1.0.9 (Recommended) 7/30/2014 http://dell.to/1AguAGX

Dell PowerVault MD 34/38 Series Storage Controller Firmware and NVSRAM firmware version 08.10.08.60 (Recommended) 7/29/2014 http://dell.to/1pPqP6t

Dell PowerVault MD 32/36 Series Storage Controller Firmware and NVSRAM firmware version 07.84.56.60 (Recommended) 7/30/2014 http://dell.to/Vp4npR

LSI SAS 9300-8e 03.00.08.00 (Recommended) 7/30/2014 http://dell.to/1yzZPd9

 

OS updates:

RHEL 7 tomcat security update https://access.redhat.com/errata/RHSA-2014:1034

RHEL 6 and 7 389-ds-base security update https://access.redhat.com/errata/RHSA-2014:1031

RHEL 7 resteasy packages security update https://access.redhat.com/errata/RHSA-2014:1011

RHEL 7 samba security advisory https://access.redhat.com/errata/RHSA-2014:1008

Update for RHEL 7 qemu-kvm packages update https://access.redhat.com/errata/RHSA-2014:0927

Update for RHEL 6 plymouth packages https://rhn.redhat.com/errata/RHBA-2014-1030.html

RHEL 6 ksg bug fix update https://rhn.redhat.com/errata/RHBA-2014-1015.html

Update for Cups packages for RHEL 6 https://rhn.redhat.com/errata/RHBA-2014-1016.html

Update for nomad packages for RHEL 6 https://rhn.redhat.com/errata/RHBA-2014-1005.html

RHEL 6 Samba4 security update https://rhn.redhat.com/errata/RHSA-2014-1009.html

Libvirt update for RHEL 6 https://rhn.redhat.com/errata/RHBA-2014-0911.html

 

PowerEdge M1000e

$
0
0

We have a Blade Chassis PowerEdge M1000e with 10 blades in it. We are only using 8 blades and two of them are power off. is it safe to pull them out of the chassis?

 

We want to add memory onto the blade. Can we just pull the power off blade out, add the memory and then bring the blade back up? Hope that we will see the memory

 

thanks

 

Is it

Can a Poweredge R410 with cabled drives be upgrade to support hot-swap by adding the hot-swap backplane and a H200 Controller?

$
0
0

I am purchasing a used R410 for home use, and believe it is of the cabled hard drive configuration, and not hot-plug/swap.   While this is not a HUGE concern, hot-swap is nicer.   Looking at the chassis pictures (and the system maintenance manual, i can't seem to tell if it is possible to convert the cabled configuration to hotswap.   Is it possible to do this, assuming I purchase the backplane, hard drive trays, and a H200 controller?

Thanks!

Removing PowerEdge R610 from Rapid Rails

$
0
0
How do I remove a R610 from Rapid Rails? I know I could try to remove the rails from the rack but I am just trying to remove the server. Thanks. Bill

R200 Unable to boot to OS

$
0
0

Hello. I'm guessing that this string has long been closed out, but it is so close to my issue that I'd like to see if I can reincarnate it; and I hope perhaps you can help me too! Please do tell me where to post this if I've got it in the wrong location.

First, my issue is with an R200 Server so that's a little different. Following a power outage the system was not coming up. A clean boot ended with an error indicating that the Dell SAS 6 Host Bus Adapter controller was bad: 'ERROR! Adapter Malfunctioning!' Fortunately, I had another system and swapped out the controller and then had to go through a similar process you already described here. The message now read:

Integrated RAID exception detected: Volume (00:130) is currently in state INACTIVE/DEGRADED. I was able to address this by going into the configuration (ctl>c) and activating the mirror. Once I did that it seemed a step closer. I believe that one of the disks was detected as missing but on bootup, I now see this message incicating that it now sees the drives: (Sorry, the editing in this box isn't working well...)

HBA ID LUN VENDOR Product Revision Capacity

1 0 0 ATA ST3250310NS NA08 232 GB

1 0 Dell Virtual Disk 1028           232 GB

LSILogic SAS1068E-IR 0.20.48.00 NV 28:06

And now, unfortuantely, I think windows tries to load, but I eventually end with this message: 'Windows could not start because the following file is missing or corrupt: \WINDOWS\SYSTEM32\CONFIG\SYSTEM. You can attempt to repair this file by starting Windows Setup using the original Setup CD-ROM. Select 'r' at the first screen to start repair.'

I have tried loading the windows setup disk to perform this operation, but when I select 'r' it tells me that it cannot find a hard disk.

Here are my questions not necessarily in this order: 1) Do you have any advice for me at this point? 2) Is it possible that I do have a missing drive in the system and need to replace it prior for the OS repair to work?

Thanks!

Viewing all 5887 articles