Quantcast
Channel: PowerEdge General HW Forum - Recent Threads
Viewing all 5887 articles
Browse latest View live

Cannot update/save settings to CMC

$
0
0
Hi First up I'm new to blades I have recently acquired a dell M1000e with 2 CMC4.5 a iKvm and a couple of blades second hand when I access the rack via the web portal using root and calvin I am unable to apply any changes however I can seem to apply some changes via CLI using the iKvm -I updated the date and time via CLI and it seems to have saved that when I try to make a change I get an error "Operation Not Successful Error= 0x2E44" im sure you need heaps more info but as I don't know what your likely to ask :) thanks in advance

R420 chassis heating due raid controller card

$
0
0

hi

we purchased 6 servers from dell india.

we are facing a severe heating issue on top of the chassis above the raid card with all these 6 servers.

server configuration

R420 - single hexcore processor 2.2 ghz, 32gb ram

4 X 600 gb 15000 rpm drives
(configured as 2 drives in raid 1 + 2 drives in raid 1)

these servers are placed in a datacenter -- temperature is around 18 deg C

we are facing a severe heating issue at the on top of the chasiss just above the raid controller

when the servers are placed one above the other like they are normally placed in a datacenter the servers heat up between 50.4 - 57 deg celcius

dell support has changed motherboard, raid card , power supply etc of one of the above servers which is non-production (heating to 50.4 deg celcius) but the issue is not resolved

On closer examination of the raid controller card i noted that the fins of the heatsink on top of the raid controller card --  instead of being parallel to the airflow is actually perpendicular to the air flow and is actually trapping all the heat

the same card in a R620 server has the heatsink fins parallel to the air flow which remains cool

has anybody else in this forum noted this and are facing such a heating issue ?

could you please check this and let me know the resolution to this problem

can the heatsink be turned around by 90 degrees so that the fins of the heat sink are parallel to the airflow ?

thanks for your help

rajesh mahadevan

mumbai , india

manuals /BIOS etc for a Dell DCS6005 3-node AMD server

$
0
0

Hi,

Maybe a desperate move to seek help here since the official support.dell.com has nothing about a Dell PowerEdge 6005 server. This is a -most likely- custom made server for a customer. It has 3-nodes of a Tyan S8208 motherboard. Two AMD2419EE cpus on each node. IPMI reports "DCS6005" as the FRU and a service tag that's not recognized by Dell.

Well, one of the nodes sends a continuous 'beep' when it powers on. No VGA console or IPMI console over LAN. So, I have no clue what might be wrong. Maybe a reset of the BIOS settings? (how?) Maybe re-flashing the BIOS? (how? I have no console!)

to cut a long story short, I'm helpless without proper documentation for *THIS* specific implementation.

Tyan re-directed me to Dell for manuals... But Dell doesn't post anything for this server (it does not exist :))

BIOS is AMI 1.09 and the management firmware is 1.03 (MegaRAC - Aster).

If anyone had the pleasure of finding any support documentation on how to bring these things back to life (or flash a new BIOS/firmware - if it ever existed). Please share. You'll do good :)

Thank you,

Thanos

Blade assistance

$
0
0

Hi all,

I am hoping someone may be able to help. Currently we use Dell r620 hosts and EqualLogic arrays. These run a VMware cluster.

I am looking at perhaps moving to a blade array system, as it will save us in many areas in the long run. I have been given different bits of info and unfortunately our Dell account management team are not providing any clarity.

My plan is to initially purchase a chassis, single blade and EqualLogic blade. Then we can expand rapidly. Discussing with someone at Dell they said that we could perhaps initially purchase the following:

  • M1000e chassis
  • m620 blade
  • m8024-k switch x2 (IO in a1/a2)
  • equallogic ps-m4110

From the info I have it looks like this would give 10gb to each blade and EQL. Further info indicates that these 10gb ports can be divided in to multiple links, which I could then do 8gb for iSCSI, 1gb for mgmt and 1gb for vm traffic. 

The external ports on the m8024 would then be connected to our Cisco core using 1gb fibre connections, brought together via etherchannel or similar. 

My query is if this kit list is correct and that this scenario would work? Also do the m8024 switches need to be linked  together in this scenario? 

Is there anything that I have missed?

thanks in advance

Simon

PE2950III Processor Support

$
0
0

Hello!

I read someplace that the PE2950III with latest BIOS can support 5600 series Xeons.

Can anyone confirm?

Thanks!


Mike

Poweredge T110 and installing video card

$
0
0

I wanted to see if anyone has had any updates regarding putting a video card into poweredge T110 and if you have what kind of video card did you use?   In order for you to install and use the video card did you have to disable something in the BIOS regarding internal video.  Any detailed info would be greatly appreciated

 

thank you

 

Dell Power Edge does not start up

$
0
0

I have a Dell R720.

whenenergized theserver.The buttonwith the letter"i"thatis in frontstays onanddoes not go outmore.Thenthe serverdoes notturn on.

The energycomes from aUPSandis withinnormalparameters.

asI canIknow thatproblem?

Problem during installing Windows Server 2008 at my Server dell

$
0
0

Hello guy!

I have a Server Dell PowerEdge T620

I did a Raid 5 for 3 Hard disk drive WD30EFRX Red drive ( each 4TB)
When I'm installing Windows Server 2008, not find hard disk, which make installation.

someone help me?

Thanks in advance


DELL R710 - 2 network cards out of 4, if active cannot be seen at the LAN

$
0
0

Hello All

I have a server R710 and it has 4 network cards on it.

I have deactivated 2 out of the 4 network cards that come from the manufacture and for the other 2 the configuration is as follows:

Network Card 1: 192.168.1.228 / 255.255.255.0, GW: 192.168.1.1, DNS: 192.168.1.224

Network Card 2: 192.168.10.8 / 255.255.0.0, GW: nothing. DNS 192.168.10.4

The thing is that if i will restart the server i cannot find it in the LAN. in any of the 2 LANS. I have to disable and then enable the Network Card 1 and after it can be seen to any of the 2 LANS.

I have another 4 Dell servers (3 R710, 1 R610) and that dont happen to them.

Any ideas?

Thx in advance

Wake On LAN

$
0
0

Hi Chris

can you help me. How can i set wake up on lan. In bios, i only see security systerm/AC recovery. I need set up it wake up on lan. Please help me. 

thanks a lot.

VRTX and M620

$
0
0

Hi everybody,

I have a VRTX with two M620s, one of the M620s gives me an error during post. the error says; 

Warning : Chassis verification failure. 
System configuration may not be correct.

I need  help with this please.

By the way both M620s have the same exact specs.

Power edge 1950 VGA Driver- Win 2000 Sever

$
0
0

Trying to locate a Driver for a PowerEdge 1950  Service Tag  <ADMIN NOTE: Service tag removed as per privacy policy> on board VGA chip running Win 2000 Sever-Service pack 4, or alternative what type is the on board VGA Chip?  Control panel reports no information per type of chip.

RAC0503 and RAC0501 with T620 and H310

$
0
0

I have a T620 with one Perc H310 connected to the backplane. 

 

In the iDrac when I go to storage I get the following error:

RAC0501: There are no physical disks to be displayed. 1. Check if the host system is powered off or shutdown. 2. Check if the physical disks are inserted into the enclosure or attached to the backplane. 3. There are no out-of-band capable controllers detected.

 

Also when I go to Physical Disk, Virtual Disk or Controller I get

RAC0503: There are no out-of-band capable controllers to be displayed. Check if the host system is powered off or shutdown.

 

I tried resetting the drac using the command and powering down, still get the same.

 

is this normal

 

thank

Dell PowerEdge 2950 II - Unsupported cpu combination System halted

$
0
0

I bought two new processors for my PowerEdge 2950 II and the place get the error below:

Unsupported cpu combination

System halted

The processors are the model Xeon E5440, socket LGA771.

The BIOS version is 2.4.3.

Using my Service Tag on the Dell site is available an update for my BIOS in version 2.7.0.

I wonder if this version really adds support to my processor.

Any risk doing this update?

Thanks,

Rodrigo Ventura.

Dell Power Edge 2950 with Dual Core 1.86ghz proc *2

$
0
0

I am trying to upgrade this server and after looking at CPU support it looks like this may take up to 3.16ghz Xeon quad core proc.

Can some one verify if either 2.66 Mhz or 3.16Mhz quad core CPUs work on this server?

i believe the originally FSB speed suggest 1066 Mhz


Cannot Install Windows Server on Dell T420

$
0
0

I have a Dell server and it was running as an EXSi server. I am in the process of reassigning it to be a HyoerV server. 

Unfortunately, I was unable to install HyperV or Windows servers. I have tried Windows HyperV 2008, Win Server 2008 R2 and Windows Server 2012.

The error "A required CD/DVD drive device driver is missing".

 

I have downloaded and burned multiple copies of the Installation CD from the MS website and can confirm it is not the CD.

 

I have upgraded the BIOS. I have not been able to update the firmaware as I havent figured it out.

 

I have seen similar problems on other threads but there solution was around the actual cd/dvd.

 

Any ideas on what is causing this issue?

Purchased Used Poweredge R710 - Came with custom firmware.. how can I reflash it back to 6.4.0

$
0
0

I purchased a Used Poweredge R710 today with no drives.
Turns out this was used for an arcsight logger.
Service tag comes up: 

PowerEdge R710

Service Tag: HNV0DQ1 Express Service Code: 38448107641

 

I would like to flash the bios on this to get it back to factory settings.

I tried the R710-060400C bios executable, I get back this error:

Cannot use a Dell Systems PowerEdge R710" Bios in a "Arcsight, Inc - 7200 Series"
Press any key to exit..

 

And it dumps me back to my bootable usb.

Arcsight is now HP, and they haven't been very helpful.

How can I force this bios firmware to bring it back to stock.

 

Thanks

R

EDIT:

I found it - had to flash the bios with the /forcetype flag.

this can be closed.

 

T410, 'Press F1 to continue, F2 to enter setup'

$
0
0

Last week our PE T410 had a PCIE failure on bus 0 and reboot.  It hung on 'Press F1 to continue, F2 to enter setup'.  Dell came out and replaced the system board but it still hangs on 'Press F1 to continue, F2 to enter setup'.  There are no error messages or reason for 'Press F1 to continue, F2 to enter setup'.  If I press F1 it boot up normally.

The server has 4 x 450GB SAS drive and I think an S300 controller.  There is also a DVD-ROM.  When the server starts, it looks like a PXE boot attempt while it looks for a DHCP server.  when this fails the POST continues.

Any suggestions?

Error code showing when there is not an error on PowerEdge 2950II

$
0
0
So a while back I posted here asking if I could replace the backplane of my poweredge 2950 without messing anything up (raid wise). The answer I got was yes since it is all hardware based, which I had thought in the first place. I went ahead and replaced it and have had a E1A14 – SAS Cable A message ever since. The server has been running that way perfectly fine like that for at least a month now. The raid or hard drives have not been affected and everything works fine. I have tried reseating the cable and I am still getting the message even though it works fine. Is there any way to dismiss this message to keep it off the lcd screen? I am only running 3 hard drives currently in slots 0,1, and 2 so does cable A service hard drive slots 3,4,and 5 thus it is not affecting me??? Thanks

Dell Poweredge 2950 III not recognizing 32gb of memory

$
0
0

i put 8 sticks of 4gb in there and it only detects 28 gb

says an error about dimm slot 7 being disabled

is this a bios setting or version issue?

Viewing all 5887 articles