R530 issue: Timeout on multiple physical disks with H330 mini

$
0
0

I have a new R530 with 8 physical disks, all straight from Dell, 2x 120G SSD OS drives, 4x400G SSD VM/DB drives in raid 10, and 2 6TB in raid 1 for file storage and backups. We've just started to put it in use and are getting the following occasional items in the alert log on all 4 of the 400GB SSDs. 

A call to Dell support told us we needed a different RAID controller and mostly just made me angry as we have very little running currently as we are migrating out of azure and only have 1 active VM. Any suggestions would be welcome and appreciated, driver and firmware appear to be up to date.

Alert Log

 2095Fri Sep 04 14:21:12 2015Storage ServiceUnexpected sense. SCSI sense data: Sense key: 6 Sense code: 29 Sense qualifier: 0: Physical Disk 0:1:2 Controller 0, Connector 0
 2095Fri Sep 04 08:45:24 2015Storage ServiceUnexpected sense. SCSI sense data: Sense key: 6 Sense code: 29 Sense qualifier: 0: Physical Disk 0:1:2 Controller 0, Connector 0
 2405Fri Sep 04 08:45:23 2015Storage ServiceCommand timeout on physical disk: Physical Disk 0:1:2 Controller 0, Connector 0
 2405Fri Sep 04 08:45:22 2015Storage ServiceCommand timeout on physical disk: Physical Disk 0:1:2 Controller 0, Connector

Firmware/Driver Information for Controller PERC H330 Mini

Firmware Version25.3.0.0016
Driver Version6.602.35.00
Storport Driver Version6.3.9600.17383