PowerEdge 610 no POST, no video, no boot. DRAC only

$
0
0

Hi, I have a T610 shows no video when powering up. I don't think it's even hitting POST. The server was working fine/without error, was virtualized several months ago and powered off. This is the first time powering it up since then. The fans come on normally and everything looks and sounds normal, but there is no video/POST.

When powered on the fans come on normally; drives 0 and 1 blink together; then 2 and 3; then they all go in sync (I believe they are configured in two RAID1 arrays but it might be a RAID5, I honestly don't remember)

I can connect to the DRAC Enterprise and view info from there - logs are pasted at the end.

Various messages show on the LCD, depending on what troubleshooting steps I take. Originally it showed a CPU1 Status: Processor sensor for CPU1, IERR was asserted which led me down the path of swapping CPUs. As it stands now, with one CPU,it just shows the system name and service tag as if all were working normally.

Steps I have taken to attempt to boot:

Remove all drives

Boot w various PSUs removed/swapped (2 PSUs in system)

Removed PCI NIC card

Removed CPU1 and replaced w CPU2 

Swapped CPUs 1 & 2

Removed RAM for CPU2 when running only CPU1

Removed backplane cable

At a loss here, any help greatly appreciated.

*******

RAC logs since the server was last shut down:

Severity Date/Time Description

System Boot Storage Cable SAS A: Cable sensor for Storage, configuration error was asserted
System Boot System Board Intrusion: Intrusion sensor for System Board, chassis intrusion was deasserted while system was ON
System Boot System Board Intrusion: Intrusion sensor for System Board, chassis intrusion was asserted while system was OFF
System Boot Storage Drive 3: Drive Slot sensor for Storage, drive removed
System Boot Storage Drive 2: Drive Slot sensor for Storage, drive removed
System Boot Storage Drive 1: Drive Slot sensor for Storage, drive removed
System Boot Storage Drive 0: Drive Slot sensor for Storage, drive removed
System Boot System Board PS Redundancy: PS Redundancy sensor for System Board, redundancy regained was asserted
System Boot PS 1 Status: Power Supply sensor for PS 1, input lost was deasserted
System Boot PS 1 Status: Power Supply sensor for PS 1, input lost was asserted
System Boot PS 1 Status: Power Supply sensor for PS 1, presence was asserted
System Boot PS 1 Status: Power Supply sensor for PS 1, presence was deasserted
System Boot PS 2 Status: Power Supply sensor for PS 2, input lost was deasserted
System Boot PS 2 Status: Power Supply sensor for PS 2, presence was asserted
System Boot PS 2 Status: Power Supply sensor for PS 2, presence was deasserted
System Boot System Board PS Redundancy: PS Redundancy sensor for System Board, redundancy lost was asserted
System Boot PS 2 Status: Power Supply sensor for PS 2, input lost was asserted
System Boot System Board Intrusion: Intrusion sensor for System Board, chassis intrusion was deasserted while system was OFF
System Boot System Board Intrusion: Intrusion sensor for System Board, chassis intrusion was asserted while system was OFF
System Boot System Board Intrusion: Intrusion sensor for System Board, chassis intrusion was deasserted while system was OFF
System Boot System Board Intrusion: Intrusion sensor for System Board, chassis intrusion was asserted while system was OFF
System Boot CPU1 Status: Processor sensor for CPU1, presence was deasserted
System Boot CPU1 Status: Processor sensor for CPU1, IERR was asserted
Mon Apr 27 13:36:54 2015 OEM event data record
Mon Apr 27 13:36:54 2015 System Software event: OS Stop sensor, OS graceful shutdown was asserted